What this source can support
Reviewed 15 August 2026 · geometry completeness 24/100 · High for the reported approximate height, national counts and 1958 cost comparison; low for tower quantities.
There is no linked dossier or replacement model. A representative tower model is possible only after obtaining drawings; current evidence supports height and functions but not steel tonnage, cage size or foundation. The operating savings of tonsvarare cannot be used as tower capital cost.
Supported useThe opening documents one anonymous preserved steel optical-air-surveillance tower in central Sweden, with an approximately 15 m ladder and a top observation cage. Most of the article is national system history: about 1,500 LS sites, manual telephone reporting, the 1958 tonsvarare line-test device, later OPUS automation, and eventual replacement by 600–700 LOMOS observation sites. It provides operating/device costs but no tower construction cost or drawings.
Geometry evidenceheight_m: value: 15 | unit: m | scope: focal tower access ladder/approximate tower height | note: The article calls the ladder approximately 15 m high; exact overall tower height is not separately stated. | inner_structure: value: steel tower with ladder, heavy timber floor hatch and top observation cage | scope: anonymous focal tower | note: Cage and foundation dimensions are absent. | other: value: 1500 | unit: LS sites | scope: national optical-air-surveillance system | note: Approximate national count, not the focal tower count.; range: 600; 700 | unit: observation sites | scope: later LOMOS replacement system | note: Different generation and program; not geometry for the focal LS tower.
Historic-cost evidenceamount: SEK 21.60 per LS test | year: 1958 | basis: operating-cost comparison | scope: Existing field-visit method: SEK 16.60 labor/test plus SEK 5 travel, assuming at most five LS per day.; amount: SEK 1.60 per LS test | year: 1958 | basis: operating-cost comparison | scope: Tonsvarare method, based on 80 LS calls/day and SEK 128 total call-plus-wage cost.; amount: SEK 25 per unit | year: 1958 | basis: manufacturing price | scope: One tonsvarare line-test device; not tower construction cost.
Systems describedObservation cage with compass plate and communications outlet; Manual telephone reporting with prioritized air-defence calls; Tonsvarare remote line-testing device; Later OPUS battery-powered data sender and LS telephone; National links from LS to LGC and onward to RRGC/LFC
Primary cost driversSteel tower and foundation; Observation cage, hatch and ladder safety; Remote-site transport and erection; Telephone/data line and lightning protection; Portfolio-wide maintenance and line testing
Unit / programme scopeOne anonymous tower is photographed, but most quantities and costs refer to the national LS system or its successor. Unit tower cost and national telecom-program cost must be modeled separately.
Revision directionIndeterminate
Missing inputsTower type drawing and overall height; Cage plan and section; Steel member sizes and mass; Foundation dimensions and ground conditions; Access/erection route; Telecom and power scope; Historic tower construction cost
Site / data issuesNo linked dossier exists for the focal LS tower.; The index record for Anonymous preserved luftförsvarsgruppcentral describes an LGC command facility, not an LS tower, and must not be used as a mapping substitute.; The article mixes focal-tower observation, national LS history, OPUS and later LOMOS; their counts are non-additive.; Reader comments asking for drawings are not geometry evidence.